STY404-AIRFORCE ULTRASONIC FLOW METER FLOWMETER COMPLETE SET CLAMP ON SENSOR(DN15-6000MM,160C)

  • This listing is for DN15-6000mm pipe size, the water temperature is from 0-160c
  • It comes with S1H transdcuer (DN15-100mm) and NEW M1H transducer (DN50-700mm); 5m*2 signal cable;metal clamp fixture; one aluminium case; tape ruler;adaptor; data line
  • You must use coupling agent when you measure the flow rate. If you do not use the silica gel, it will have no signal

It comes with factory issued calibration certificate

 

 

Typical Applications 

 

The STY404 flow meter can be virtually applied to a wide range of measurements. The measured pipe ranges 20-6000 mm [0.5 - 200 inch]. A variety of liquid applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent, etc.   Because the instrument and transducers are non-contacting and have no moving parts, the flow meter can not be affected by system pressure, fouling or wear. Standard transducers are rated to 110 ºC.   Higher temperatures can be accommodated. For further information, please consult the manufacturer for assistance. 

 

Data Integrity and Built-in Time-Keeper 

 

All user-inputted configuration values are retained in the built-in non-volatile flash memory that can store them for over 10 years, even if power is lost or turned off. Password protection is provided to avoid inadvertent configuration changes or totalizer resets.  A time-keeper is integrated in the flow meter for the index of date totalizing and works as the time base of flow accumulation. It keeps operating as longas the battery’s terminal voltage is over 1.5V.  In case of battery failure, the time-keeper will not keep running and it will lose proper time values. The user must re-enter proper time values in case the battery becomes totally exhausted. An improper time value affects no other functions but the date totalizer.   

 

 

 

 

 

 

 

 

 

 

 

Specifications:

 

Linearity

: 0.5%

Repeatability

: 0.2%

Accuracy

: ±1% of reading at rates>0.2 mps

Response Time

: 0-999 seconds, user-configurable

Velocity

: ±32 m/s

Pipe Size

: This listing is for 15mm to 6000mm only.

(Free 1 set of 6000mm probe)

Rate Units

: Meter, Feet, Cubic Meter, Liter, Cubic Feet, USA Gallon, Imperial Gallon, Oil Barrel, USA Liquid Barrel, Imperial Liquid Barrel, Million USA Gallons. User configurable.

Totalizer

: 7-digit totals for net, positive and negative flow respectively

Liquid Types

: Virtually all liquids

Security

: Setup values Modification Lockout. Access code needs unlocking

Display

: 4x16 English letters

Communication Interface

: RS-232C, baud-rate: from 75 to 57600. Protocol made by the manufacturer and  compatible with that of the FUJI ultrasonic flow meter. User protocols can be made on enquiry.

Transducers

: Model M1 for standard, other 3 models for optional

Transducer Cord Length

: Standard 2x10 meters, optional 2x 500 meters

Power Supply

: 3 AAA Ni-H built-in batteries. When fully recharged it will last over 10 hours of operation.100V-240VAC for the charger

Data Logger

: Built-in data logger can store over 2000 lines of data

Manual Totalizer

: 7-digit press-key-to-go totalizer for calibration

Housing Material

: ABS

Case Size

: 100x66x20mm

Handset Weight

: 514g (1.2 lbs) with batteries

 