• Filter
Created on: 18 February 2014

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to    five minutes when the “PUSH BUTTON SWITCH”    and “TIMER ON BUTTON” are pressed together.  ● This will keep test “ON” for the duration of the timer.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 163(L) × 100(W) × 50(D)mm Weight (battery included) Approx. 460g Power source 1.5V (AA) × 6 Safety standards IEC 1010 CAT II 30V

Created on: 19 February 2014

FEATURES ● Safely operates at low voltage       ● Measures system voltage.● Measures capacitance of test point if system voltage is known.● Checks phase rotation of cables.● Phases out cables.● Rugged - comes with portable case.● Operates from potential test point of elbow connec-tors.● Battery operated.      SPECIFICATIONS       Voltage ranges 0~16kV / 0~32kV Accuracy ±8% (exclusive of tap capacitance variations) Tap capacitance setting 0.4 to 3.0 pF continuous per channel Frequency 50 or 60 Hz Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1420g Power source 1.5V (AA) × 4 Safety standard EN 61326-1

Created on: 19 February 2014

FEATURES ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.     SPECIFICATIONS       Voltage / power input     Universal IEC LEAD 240V/10A Wiring polarity check     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Elcb / rcd tester     Nominal Voltage 240Vac Frequency 50/60Hz Current Tolerance (current proportional to Line to Earth Voltage) ±10% Universal test sockets     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Fuse 10A Appliance tester     Nominal...

Category: Terminal
Created on: 21 February 2014

Sockets nylon    4 m/m sockets with shrouded    contact compatible with shrouded .    plugs and leads supplied with nuts    for panel mounting.     TER-6200B Black     TER-6200R Red    TER-6200G Green

Created on: 18 February 2014

● 8 voltage settings: 240Vac, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, and 275kV.● High bright LED visual indication.● Sound indication.● Easy-to-prove method.● Self-test selection.● Use 3 × 1.5V “C” batteries.● High impact nylon casing.● Non-contact work by proximity.● Compatible with most link sticks.● Lightweight, robust, & compact.● Suitable for indoor and outdoor use.● Detects low voltage on any systems.● Easy access to batteries.● No special parts needed.● Meets EN 61326-1  EN 55011  EN 61000-4-2  EN 61000-4-3● United States Design Patent : US D474, 705 S● Special ranges are available upon request.

Created on: 19 February 2014

FEATURES ● Designed for RJ45/RJ11 modular cables, 10/100   base-T cable and Token Ring cable.● The LAN cable tester can verify cable continuity,    open, short circuit and miss-wired. ● The remote receiving unit is available for installed   cables far away either on the wall plates or on the    patch panels.● Auto and manual scan functions.● Ground wire test.         ● Lock status function.● Buzzer sound warning for wire status.● Display : LED indication for wire status.     SPECIFICATIONS       Display LED Operating temperature 0°C ~ 40°C Dimensions Master unit 132(L) × 55(W) × 39(D)mm Remote receiving unit 74(L) × 30(W) × 25(D)mm Weight (battery included) Master unit : 148 g Remote receiving unit : 33g Power source 9V × 1 Safety standard EN 61326-1

Created on: 19 February 2014

FEATURES ● Microprocessor-controlled.● 68 x 34mm large LCD display.● 3½ digital LCD (2000 counts) a LCD indicated instrument for    insulation(MΩ), continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● Auto ranging.● Auto power off function.● Auto data hold function.● Rel function (ohm only)● Continuity buzzer.● External AC voltage warning.● Automatic circuit discharge.● BS 16th edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20.00MΩ 0-200.0MΩ 0-2000MΩ Output voltage open circuit Rated test voltage +10% Accuracy 20MΩ : ±(1.5%rdg+2dgt) 200MΩ : ±(2.5%rdg+2dgt) 2000MΩ : ±(5%rdg+3dgt) Resolution 0-20.00MΩ : 10kΩ 0-200.0MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-500V Resolution 1V Accuracy ±(1.5%rdg+3dgt) Continuity     Ranges 20Ω / 200Ω / 2000Ω Resolution 0-20Ω : 0.01Ω...

Category: Bench Type
Created on: 20 February 2014

Precision meters for plant maintenance, field servicing and    educational purposes. ● Taut Band movement with rectifier type. ● Multi terminals (4mm socket) for range selection. ● Carbon pointer, mirror scale to eliminate parallax error. ● High resistance to shock and vibration. ● Accuracy:±1.5% F.S. ● Scale length:80mm. ● Dimension:107(L) × 117(W) × 53(D)mm. ● Weight:Approx. 300g.