Fluke

  • Filter
Category: Calibrators
Created on: 14 February 2014

Sources and measures dc voltage, current, resistance, RTDs and thermocouples Precision pressure measurement using Fluke 700 or 525A-P series pressure modules Includes 24 V dc transmitter loop power supply Measures 4-20 mA loop current Includes automated switch-test function Accepts ITS-90 coefficients for accurate SPRT measurements Compatible with MET/CAL Calibration Software

Category: Calibrators
Created on: 14 February 2014

Measure mA signals for PLC and control system analog I/O Measure 4 to 20 mA output signals from transmitters without breaking the loop Best in class 0.2 % accuracy Resolution and sensitivity to 0.01 mA Hold function captures and displays changing measurements Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatic power off after 15 minutes and 2 minute automatic off for backlight and spotlight

Category: Calibrators
Created on: 14 February 2014

Measure 4 to 20 mA signals without ”breaking the loop” just like the innovative and popular Fluke 771 Process Milliamp Clamp meter Source 4 to 20 mA signals for testing control system I/O or I/Ps Simulate 4 to 20 mA signals for testing control system I/O Measure 4 to 20 mA signals with in-circuit measurement Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters Source mA output signals in a linear ramp or 25 % step output– Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life

Category: Calibrators
Created on: 14 February 2014

DC voltage measurement to verify 24 V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp Output mA signal enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators Voltage output linear ramp or 25% step output Automatically change the voltage output for remote testing

Category: Calibrators
Created on: 14 February 2014

DMM and loop calibrator in one tool Precision 1000V, 440 mA digital multimeter Measure ac and dc volts, ac and dc current, resistance, continuity, and frequency 0.1% dc voltage accuracy 0.05% dc current accuracy, 1 A resolution to 30 mA Simultaneous mA and % of scale readout True rms ac voltage measurement to 1 kHz Frequency measurement to 20 kHz Min/Max/Average/TouchHold/Relative modes Diode test and continuity beeper DC current source/loop calibrator 20 mA current source/simulator Simultaneous mA and % of scale readout Manual step (25%, coarse, fine) plus auto step and auto ramp Clear LCD with backlight; 4,000 counts (30,000 counts for dc current) Externally accessible battery for easy battery changes 1000V overload protection on V, ohms, frequency 150V overload protection on mA, backed-up by 440 mA 1000V fuse Designed to meet 1000 volt IEC 1010 Cat III standards

Category: Calibrators
Created on: 14 February 2014

24 V Loop power supply HART mode setting with loop power (adds 250 ohm resistor) 100 % larger dual display 1,200 ohm drive capability on mA source Enhanced backlight with two brightness settings 0-100 % mA Span Check buttons to toggle between 4 and 20 mA Infrared I/O serial port compatible with FlukeView® Forms Software Version 2.1 (available Feb. 2003) Externally accessible fuses for easy replacement DMM designed to meet 1000 volt IEC 1010 CAT III standards Precision 1000 V, 440 mA true-rms digital multimeter Frequency measurement to 20 kHz Min/Max/Average/Hold/Relative modes Diode Test and Continuity Beeper Simultaneous mA and % of scale readout 20 mA dc current source / loop calibrator / simulator Manual Step (100 %, 25 %, Coarse, Fine) plus Auto Step and Auto Ramp Externally accessible battery for easy battery changes

Category: Calibrators
Created on: 14 February 2014

Display pressure readings in any of 10 different pressure units you specify in the calibrator setup Rugged urethane molded case protects the module from rough handling and harsh conditions Features internal temperature compensation from 0°C to 50°C for full-accuracy performance Includes NIST-traceable calibration certificate Module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source One year warranty

Category: Calibrators
Created on: 14 February 2014

Display pressure readings in any of 10 different pressure units you specify in the calibrator setup Rugged urethane molded case protects the module from rough handling and harsh conditions Features internal temperature compensation from 0°C to 50°C for full-accuracy performance Includes NIST-traceable calibration certificate Module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source Certified by CSA: I.S. Class I, Div 1, Groups A-D T4, Ta = 0 °C to 50 °C ATEX II 1G EEx ia IIC T4 Compliant. One year warranty